Just realized I've been brushing the wrong way for 6 months, and a fireplace in Rochester tipped me off
So I'm up in Rochester last Tuesday doing a routine sweep on a pretty old fireplace, and when I pulled the brush back out the flue I saw these shiny streaks on the low side of the tile liner. Not from creosote, from the brush itself rubbing the same spot thin. Took me a minute to figure out what it meant, but I'd been running the brush up at a slight angle on these 8x13 flues so the head would clear the smoke shelf, and that angle was grinding one wall the whole time. I checked my notes and I'd done it on 14 jobs since March without catching it. Switched to a shorter head with a flexible whip and went back straight up, and the liners look clean with no marks. The touch-up cost me a Saturday and about $60 in parts, but I'm glad it happened on my own schedule. Anybody got a trick for keeping the rod dead vertical in a tight flue, or do you just eyeball it like me and hope for the best?
Man, I feel this. I switched to a short whip head too and it was a game changer for keeping the rod straight in tight flues, way less eyeballing and hoping.