That $2,400 laser level on the Matthews job was off by 3/16 over 30 feet and nobody checked
Last month we were setting wall track on a 200 foot run at a job site off Matthews-Mint Hill Road and the foreman kept blaming the concrete guy for the slab being out of level, but I grabbed my old 6 foot spirit level and ran it along the track, and a 3/16 inch gap showed up over about 30 feet. Turns out nobody had checked the laser level's calibration since it came out of the case in January, and these things drift when they ride around in a truck bed all day, especially in the cold. Here's what gets me: everybody trusts the dot on the wall because it's a $2,400 tool, but the manual says to verify it on a known level line once a month and I've never seen a single crew actually do it. We ended up pulling every anchor and re-shimming 40 feet of track, which cost us about 6 hours and a whole box of wedges. I've started keeping a 6 foot level clipped to my cart and checking the laser against it first thing every morning before anyone trusts the line, and so far it's caught two other small drifts on other jobs. The other guys on my crew think I'm being paranoid, but has anyone else had a laser go out of whack mid-job and did you catch it before the pour or after?