Spent 6 hours on a "dead" zone in a brick house in Albany only to find a loose neutral on the keypad wire
The zone tested fine at the panel, failed at the door, and passed again after I wiggled the wire, which sent me chasing a ghost through three rooms of old plaster until I finally put a meter on that neutral at 4pm and saw it flicking between 0 and 12 volts, so now I meter first instead of trusting the keypad readout, anybody got a better trick for finding a bad splice behind finished walls?
Been there, done that, got the t-shirt. Chased a "bad sensor" around a two story for half a day once and it turned out to be a nicked wire stapled too tight behind the drywall, reading fine till the house warmed up. Meter on the wire beats staring at the keypad every single time, those readouts lie to you. For finding the bad spot, I'll tap the wall with the back of my hand and watch the meter, a loose splice will jump when you thump near it. Also a cheap tone tracer clipped to the neutral can help you follow it room to room without opening everything up, way faster than pulling plaster.