Update: That Frigidaire ice maker call in Tempe took me 4 hours yesterday
I mean, everyone says it's a quick fix, just swap the module. But this one had a cracked water inlet tube behind the freezer wall, and the diagnostic code was pointing to the motor. I had to pull the whole unit out and trace the line with a mirror. Has anyone else run into a hidden leak throwing off the whole system like that?
3 comments
Log in to join the discussion
Log In3 Comments
nelson.wren24d ago
Was it the plastic elbow connector that cracked? Those things get brittle from the freeze-thaw cycles and can leak just enough to mess with the pressure. I've found that a slow leak there can trick the sensor into thinking there's a motor issue because it never gets a full fill signal.
8
rodriguez.mia24d ago
My neighbor's sprinkler system had that exact problem last spring. The repair guy said those plastic elbows fail all the time in older setups.