Warning: people keep calling a shorted coax a "ground loop" and it's costing us hours
Had a nav radio acting up in a hangar out at Addison and the first guy on it wrote "ground loop" on the squawk sheet and walked off. I pulled the coax out of the tray and found the shield crushed against a rib clip about 14 inches back, reading a dead short to airframe. A real ground loop is a way you bond stuff, not a name for any random noise you can't figure out. It matters because the next guy reads that note, orders a box, and we burn a whole shift on a problem that was one chafed run all along. If the shield reads shorted to structure with a meter, that is a bad cable, so write it that way and save everyone the trouble. What's the worst mislabeled squawk you've seen left on a sheet for the next shift?
The real cost of a junk squawk like that is it trains the next shift to trust the sheet less, and once a crew stops believing the notes they start re-doing every check from scratch. A guy who writes "ground loop" for a crushed shield isn't just wrong, he's teaching everyone after him that the paperwork is noise. Fix the writing habit and you save more time than any one repair ever will.